KPKSKDKXKZ

KP SERIES
TEMPERATURE CONTROL WITH SPST SWITCH
Terminal 3-4 closes at temperature rise
In general type KP is classified into 2 basic versions:
A: KP with standard switching differential
B: KP with wide switching differential
Rating at 250 V 50 Hz
3-4:6(6) A
Temperature characteristic data
Operating range: -40~+40℃
Adjusting range: A: 4 to 30K
        B: 5 to 15K
Switching differential: A: 3 to 14K
            B: 10 to 25K

Capillary type: shape A (standard)
        Shape B (on request)
Typical applications: refrigerating, freezing devices, automobile air conditioning

KS SERIES
Terminal 3-4 closes at temperature rise
Closing with rising temperature and possibility to manually initiate a defrost function is achieved by pressing the defrost pin(stroke approx. 4mm) until latching. By this the main switch is opened and locked until the defrost temperature is reached at the sensing point of the capillary which normally is fixed at the evaporator.
After the defrost temperature has been achieved, the pressure pin returns to its OFF position and the normal ON/OFF operation of the temperature control is reset. Defrost function can be initiated in any position of the dial shaft if it has been initiated by accident, the defrost function can be cancelled by turning the dial shaft to OFF position.
Rating at 250 V 50 Hz
3-4: 6(6)A
Temperature characteristic data
Adjusting range: 4 to 14K
Switching differential: 4 to 14K
Defrost temperature: possible between +2 and +10℃ (but differential of defrost temperature to warm-in min.4℃)
Capillary type: shape A (standard)
        Shape B (on request)
Typical applications: refrigerating, freezing devices, automobile air conditioning

KD SERIES
TEMPERATURE CONTROL WITH SPST SWITCH AND AUXILIARY SWITCH FOR OFF POSITION. AUTOMATIC DEFROST FUNCTION BY CONSTANT CUT-IN VALUE
Terminal 3-4 closes at temperature rise
Terminal 3-6 opens in off position
Temperature characteristic data
Operating range: -32~+6℃
Adjusting range: 4 to 18K
Constant cut-in value: +2 to +8K
Capillary type: shape A (standard)
        Shape B (on request)
Typical applications: refrigerators


KX SERIES
TEMPERATURE CONTROL WITH S.P.S.T.SWITCH AND SIGNAL SWITCH
Terminal 3-4 closes at temperature rise
Terminal 3-6 closes when warning temperature has been reached
Rating At 250 V 50 Hz
3-4:6(6)A
3-6:0.1A
Operating range:   -40~+40℃
Adjustment range:  4~30K
Switching differential:  3~14K
Signal differential:     4~7K
Capillary type:Shape A(standard)
        Shape B(on request)